* TEMPERATURE RANGE:OPERATING 0℃~40℃, OPERATING TEMPERATURE: -20℃~80℃
* HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 60 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 60 SECOND
* EFFICIENCY:TYPICAL >80% AT 115VAC, 20%~100% MAX LOAD
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS
* OVER POWER PROTECTION:110% ~ 180%
* OVER VOLTAGE PROTECTION:+5V→5.9V~6.7V、+12V→13.0V~15.0V、+3.3V→3.9V~4.3V SHORT
* SHORT CIRCUIT PROTECTION:+5V, +3.3V, +12V, -12V, AUTO-RECOVERED: +5VSB
* OVER CURRENT PROTECTION: +3.3V: 27.5~37.5A, +5V: 27.5~37.5A, +12V: 44~76.8A
* EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* SAFETY: TO MEET UL, CUL, TUV, CCC
* REMOTE ON/OFF CONTROL
THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY).
AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.
* N+1 REDUNDANCY FUNCTION
* HOT-SWAPPABLE FUNCTION
* CURRENT/BALANCE LOAD SHARING DESIGN
* +3.3V REMOTE SENSING
* ISOLATION: BUILT-IN IN POWER MODULE
* POWER FACTOR CORRENTION: ACTIVE (MEET IEC-1000-3-2)
* COOLING: 40mm DC FANS (one module)
* DIMENSION:276(D)×101(W)×82(H) mm
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |